Line register vs Basis of Design

Fifteen lines against three BoD rules: design pressure, design temperature and insulation checked, conflicts flagged for review.

Input

BASIS OF DESIGNACD-BOD-0001

Basis of Design & Operation/Control Philosophy

Revision
Rev 0
Section
3.6 Design rules and margins
Scope
Design pressure, temperature, insulation
LINE REGISTERACD-REG-0001

Master Tag Registers, Lines sheet

Revision
Rev 0
Filter
ACD-300-001
Lines
15
Design pressuremax(1.10 x op, op + 175 kPa), rounded up to the next 25 kPa. Pump discharge lines follow shutoff head + max suction pressure instead.
Design temperatureMaximum operating temperature + 15 deg C minimum.
Insulation codeRegister column matches the line-number suffix and the service temperature. Codes per BoD: H hot, C cold, ET traced, N none.

The source documents are not shown: registers and design bases stay inside your project. The check below runs on a hypothetical plant (ACD), presented the way consistency results arrive.

What Plexus does

  1. 01Reads the line register and the BoD design rules into one structure.
  2. 02Computes the required design pressure and temperature for each line from its operating values.
  3. 03Compares register values and insulation codes against the rules.
  4. 04Marks each result pass, conflict or check; the engineer confirms and corrects the register.

Output

0 / 45 rule checksrun first, then export

This animation illustrates the Plexus workflow on a hypothetical plant (ACD). In the product, rule checks run server-side and every value keeps provenance to its source document; an engineer reviews and confirms.

Source documents: ACD-BOD-0001 Rev 0 and ACD-REG-0001 Lines sheet, hypothetical plant

Line and operating conditionsDesign pressureDesign temperatureInsulation code
DN200-EFG-3001-1SS1-Hop 150 deg C · 320 kPa(g)
DN150-CAC-3002-1SS1-Nop 40 deg C · 300 kPa(g)
DN150-CAC-3003-1SS1-Cop 8 deg C · 280 kPa(g)
DN80-CAC-3004-1SS1-Cop 8 deg C · 250 kPa(g)
DN80-H2-3005-1SS1-Cop 8 deg C · 250 kPa(g)
DN80-H2-3006-1SS1-Nop 10 deg C · 230 kPa(g)
DN50-FL-3007-1SS1-Nop 10 deg C · 230 kPa(g)
DN25-SCW-3008-1SS1-ETop 30 deg C · 400 kPa(g)
DN40-SCW-3009-1SS1-Cop 10 deg C · 230 kPa(g)
DN25-SCW-3010-1SS1-Nop 10 deg C · 400 kPa(g)
DN150-CWS-3011-1CS1-Nop 30 deg C · 400 kPa(g)
DN150-CWR-3012-1CS1-Nop 40 deg C · 300 kPa(g)
DN40-FL-3014-1SS1-Nop 40 deg C · 0 kPa(g)
DN80-CHS-3015-1CS1-Cop 0 deg C · 400 kPa(g)
DN80-CHR-3016-1CS1-Cop 6 deg C · 300 kPa(g)

Manual: 2-4 hours
With Plexus: 15-30 min review (estimate, one-sheet line register against three BoD rules)