← All examplesDesign pressuremax(1.10 x op, op + 175 kPa), rounded up to the next 25 kPa. Pump discharge lines follow shutoff head + max suction pressure instead. Design temperatureMaximum operating temperature + 15 deg C minimum. Insulation codeRegister column matches the line-number suffix and the service temperature. Codes per BoD: H hot, C cold, ET traced, N none.
Next examplePump RFQ generation →
PLEXUS EXAMPLE · 04
Line register vs Basis of Design
Fifteen lines against three BoD rules: design pressure, design temperature and insulation checked, conflicts flagged for review.
Input
BASIS OF DESIGNACD-BOD-0001
Basis of Design & Operation/Control Philosophy
- Revision
- Rev 0
- Section
- 3.6 Design rules and margins
- Scope
- Design pressure, temperature, insulation
LINE REGISTERACD-REG-0001
Master Tag Registers, Lines sheet
- Revision
- Rev 0
- Filter
- ACD-300-001
- Lines
- 15
The source documents are not shown: registers and design bases stay inside your project. The check below runs on a hypothetical plant (ACD), presented the way consistency results arrive.
What Plexus does
- 01Reads the line register and the BoD design rules into one structure.
- 02Computes the required design pressure and temperature for each line from its operating values.
- 03Compares register values and insulation codes against the rules.
- 04Marks each result pass, conflict or check; the engineer confirms and corrects the register.
Output
0 / 45 rule checksrun first, then export
This animation illustrates the Plexus workflow on a hypothetical plant (ACD). In the product, rule checks run server-side and every value keeps provenance to its source document; an engineer reviews and confirms.
Source documents: ACD-BOD-0001 Rev 0 and ACD-REG-0001 Lines sheet, hypothetical plant
| Line and operating conditions | Design pressure | Design temperature | Insulation code |
|---|---|---|---|
| DN200-EFG-3001-1SS1-Hop 150 deg C · 320 kPa(g) | |||
| DN150-CAC-3002-1SS1-Nop 40 deg C · 300 kPa(g) | |||
| DN150-CAC-3003-1SS1-Cop 8 deg C · 280 kPa(g) | |||
| DN80-CAC-3004-1SS1-Cop 8 deg C · 250 kPa(g) | |||
| DN80-H2-3005-1SS1-Cop 8 deg C · 250 kPa(g) | |||
| DN80-H2-3006-1SS1-Nop 10 deg C · 230 kPa(g) | |||
| DN50-FL-3007-1SS1-Nop 10 deg C · 230 kPa(g) | |||
| DN25-SCW-3008-1SS1-ETop 30 deg C · 400 kPa(g) | |||
| DN40-SCW-3009-1SS1-Cop 10 deg C · 230 kPa(g) | |||
| DN25-SCW-3010-1SS1-Nop 10 deg C · 400 kPa(g) | |||
| DN150-CWS-3011-1CS1-Nop 30 deg C · 400 kPa(g) | |||
| DN150-CWR-3012-1CS1-Nop 40 deg C · 300 kPa(g) | |||
| DN40-FL-3014-1SS1-Nop 40 deg C · 0 kPa(g) | |||
| DN80-CHS-3015-1CS1-Cop 0 deg C · 400 kPa(g) | |||
| DN80-CHR-3016-1CS1-Cop 6 deg C · 300 kPa(g) |
Manual: 2-4 hours
With Plexus: 15-30 min review (estimate, one-sheet line register against three BoD rules)